Main PageProduct PageLiterature PageTechnical Data PageWhats New PageLocation PageCareer PageContact RM Energy PageSite Map Page
R&M Energy Systems
10586 US Highway 75 North
Willis, TX 77378
Tel : 936-890-1064
Tel : 877-465-8600
Fax : 936-890-9595

Moyno Ultra-Drive® Drive Heads

Moyno Ultra-Drive Drive Heads Applicaton Graphic Moyno Ultra-Drive Drive Head Installation Graphic Moyno Ultra-Drive Drive Head Belt Guard Cutaway Graphic Moyno Ultra-Drive Drive Head Belt Guard Cutaway Close Up Graphic

Moyno Ultra-Drive® Down-Hole Pump Drive Heads from R&M Energy Systems combine maximum operating efficiency and advanced design to provide efficient down-hole performance in the oilfield.

All Ultra-Drive Down-Hole Pump Drive Heads incorporate the following value-added features:

  • Cost effective choices for every PC pump application
  • Safe and reliable operation over the life of the drive
  • Simple to operate
  • Easy operator access to sheaves via hinged belt guards
  • Low cost maintenance
  • Low profile for visually sensitive areas
  • Multi-point lifting for easy installation
  • Single-point belt tension simplifies maintenance
  • Braided rope packing for effective shaft sealing
  • Versatility to use gas and electric prime movers
  • Automatic recoil control
  • Environmentally friendly stuffing box
  • Easy to install with removable stuffing box assembly
  • Precision space out of rotor with hollow shaft
  • Engaged brake during pick-up by rigs, flush-bys, and pickers ensures maximum safety
  • Adjustable bracing system designed for slant wells and 75 - 300 HP applications adds stability and reinforcement
  • Flanged or pin-style wellhead connections provide installation flexibility
  • Designed for 1-1/4" or 2-1/16" polished rods for application versatility

Drive Head Specification Chart

Model AA4 AD1 BD1

 

Moyno Ultra-Drive Model AA4 Moyno Ultra-Drive Model AD1 Moyno Ultra-Drive Model BD1
Shaft Type Hollow Hollow Hollow
Polish Rod Sizes 1-1/4" 1-1/4" 1-1/4"
Drive Ratio 3.78:1 1:1 1:1
Maximum Torque 500 ft/lbs. 450 ft/lbs. 1,650 ft/lbs.
Maximum Power Rating 15 hp 20 hp 60 hp
Maximum Polished Rod Speed 460 rpm 600 rpm 600 rpm
Standard Thrust Bearing 13,700 lbs. 13,700 lbs. 17,840 lbs.
Maximum Driven Sheave 16" 25" 31-1/2"
Wellhead Connection 2-7/8" EUE Pin 2-7/8" EUE Pin Threaded Pin
or
3-1/8" 3000 lbs.
Model DA3 DD1 DD1H

 

Moyno Ultra-Drive Model DA3 Moyno Ultra-Drive Model DD1 Moyno Ultra-Drive Model DD1H
Shaft Type Hollow Hollow Hollow
Polish Rod Sizes 1-1/4" - 1-1/2" 1-1/4" - 1-1/2" 1-1/4" - 1-1/2"
Drive Ratio 3:1 1:1 1:1
Maximum Torque 2,250 ft/lbs. 2,250 ft/lbs. 2,250 ft/lbs.
Maximum Power Rating 60 hp 150 hp 150 hp
Maximum Polished Rod Speed 450 rpm 600 rpm 600 rpm
Standard Thrust Bearing 80,369 lbs. 17,840 lbs.  
Maximum Driven Sheave 24" 31-1/2" 31-1/2"
Wellhead Connection Threaded Pin
or
3-1/8" 3000 lbs.
Threaded Pin
or
3-1/8" 3000 lbs.
Threaded Pin
or
3-1/8" 3000 lbs.
Model DHH EX1

 

Moyno Ultra-Drive Model DHH Moyno Ultra-Drive Model EX1
Shaft Type Hollow Hollow
Polish Rod Sizes 1-1/4" 1-1/2" & 2-1/16"
Drive Ratio 4:1 1:1
Maximum Torque 1,750 ft/lbs. 4,000 ft/lbs.
Maximum Power Rating 75 hp 300 hp
Maximum Polished Rod Speed 600 rpm 600 rpm
Standard Thrust Bearing 17,840 lbs. n/a
Maximum Driven Sheave 24" 35-1/2"
Wellhead Connection Threaded Pin
or
3-1/8" 3000 lbs.
3-1/8" 3000 lbs.

Variable Frequency Pump Controller Specifications

1336 Plus II AC Drive

The 1336 Plus II AC Drive features Sensorless Vector Control for superior torque production and speed control. Additional features include the following:

  • Load loss detection
  • Easily programmable parameters organized in a group and element structure
  • Proactive current limit for rod protection
  • Sturdy NEMA type 3R enclosure
  • Optional temperature controls
  • Sub-control panel with HIM and operator devices
  • Control terminal blocks for easy installation
  • 120 VAC Control transformer
  • Fused lightning and surge arrestor

1336 IMPACT™ AC Drive

For superior torque regulation and speed control, the 1336 IMPACT AC Drive, with Force Technology™, is the preferred option. Additional features include the following:

  • Encoderless field oriented control
  • Patented current regulator for precise torque control
  • Proactive torque limit for rod protection
  • Sturdy NEMA type 3R enclosure
  • Control terminal blocks for easy installation
  • Sub-control panel with HIM and operator devices
  • 120 VAC Control transformer
  • Fused lightning and surge arrestor
  • Optional temperature controls

Literature

back to product listing

Check R&M Energy Email Write to R&M Energy